Date: 7/8/2010 | Time: 09:30 AM | Report ID: 039-070810 |
Property: |
Customer: |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this building. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this building or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
In Attendance: Vacant (inspector only) | Approximate age of building: Over 50 Years, Over 25 Years | Temperature: Over 65 |
Weather: Hot and Humid, Cloudy | Ground/Soil surface condition: Dry | Rain in last 3 days: Yes |
Radon Test: No | Water Test: No |
Viewed roof covering from: Walked roof | Roof-Type: Flat | Roof Covering: Rubber membrane |
Roof Structure: Wood Post and Beam |
Items
|
1.0.A | Roof Coverings Comments: Inspected, Repair or Replace | ||||||
(Picture 3) Rubber roof membrane is from 1989. (Picture 4) (Picture 5) Rubber roof is torn at southwest corner. (Picture 6) Signs of water ponding at north wall. Roof slope should be corrected at this location. Signs of roof leak found at this location in roof structure. |
1.1.A | Roof Flashings Comments: Inspected, Repair or Replace | |||||
(Picture 2) Roof covering is pulling loose from parapet through-wall drains. (Picture 3) Several coping caps around perimeter of warehouse are not secured. Several caps are missing at southwest corner. (Picture 4)(Picture 5) Roof photos. |
1.2.A | Roof Ventilation Comments: Inspected |
1.3.A | Roof Drainage Systems Comments: Inspected | ||||
(Picture 2) Elevator shaft roof drain is leaking. Brick at this location is damaged. (Picture 3) Wood beams on roof are covering drain. Drain cover is missing. (Picture 4) Roof has pulled loose from parapet walls at southwest location. Parapet wall coping cap is missing at this location. Rubber roof membrane is not adhered to this section of roof. |
1.4.A | Roof Structure and Attic (report leak signs or condensation) Comments: Inspected, Repair or Replace | |||
(Picture 3) Roof boards have been replaced/reinforced, roof has continued to leak since repairs have been made. |
Viewed roof covering from: Walked roof | Roof-Type: Gable | Roof Covering: Metal |
Roof Structure: 2 X 4 Rafters Pre-engineered Steel Purlin and Girder System | Attic Insulation: Fiberglass R-19 |
Items
|
1.0.B | Roof Coverings Comments: Inspected, Repair or Replace | |||
|
Siding Style: Brick | Siding Material: Full brick | Exterior Entry Doors: Wood |
Items
|
2.0.A | Wall Cladding Flashing and Trim Comments: Inspected | ||
|
2.1.A | Doors (Exterior) Comments: Inspected, Repair or Replace | ||
|
2.2.A | Windows Comments: Inspected, Repair or Replace | ||||
Holes found in window glass. Window sashes, sills, and glass need to be repaired/maintained to prevent further water intrusion and structural deterioration to brick. |
2.3.A | Foundation Walls and Mortar Joints Comments: Inspected | |
|
2.4.A | Other Comments: Inspected | |
|
Siding Style: Drop | Siding Material: Metal | Exterior Entry Doors: Steel |
Items
|
2.0.B | Wall Cladding Flashing and Trim Comments: Inspected, Repair or Replace | |||||||
(Picture 2)(Picture 3) (Picture 7) Bottom of siding is rusted through in several locations on west side of building. (Picture 4)(Picture 5) Siding is bent/damaged in several locations around building. (Picture 6) Damaged siding above overhead door. |
2.1.B | Doors (Exterior) Comments: Inspected, Repair or Replace | |||||
Overhead doors are sealed, unable to operate doors and dock levelers at this time. Levelers appear to be in good operating condition. (Picture 3) Second overhead door on east wall is missing a roller pin (Picture 4) at top left corner. (Picture 5) Cables are cut. |
2.2.B | Foundation Walls and Mortar Joints Comments: Inspected, Repair or Replace | ||||||
(Picture 2) Opening on west side is properly supported. (Picture 3) (Picture 4) Mortar joints are washing out around perimeter of building. Loose mortar joints need to be tuck pointed. |
2.3.B | Vegetation, Grading, Drainage, Driveways, Patio Floor, Walkways and Retaining Walls (with respect to their effect on the condition of the building) Comments: Inspected, Repair or Replace | |
|
2.4.B | Polarity and Grounding of Receptacles on Exterior Walls of Inspected Structure Comments: Inspected, Repair or Replace | |
|
Foundation: Brick Poured concrete | Method used to observe Crawlspace: Walked | Floor Structure: Wood beams |
Wall Structure: Brick | Columns or Piers: Conrete piers Steel lally columns Steel screw jacks |
Items
|
3.0.A | Foundations, Basements and Crawlspaces (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) Comments: Inspected | |
|
3.1.A | Walls (Structural) Comments: Inspected | ||||
(Picture 1) Post jacks/columns added on each floor to distribute loads through building. (Picture 1 & 2) Bracing used to tie wall back to three wood beams to stop movement of wall. (Picture 2) Through-bolts used to prevent brick from moving outward. (Picture 3) Reinforcement on 3rd floor. (Picture 4) Footings in basement to support load transferred from above floors. | |||||
| |||||
|
3.2.A | Columns or Piers Comments: Inspected, Repair or Replace | ||
|
3.3.A | Floors (Structural) Comments: Inspected, Repair or Replace | ||
| |||
| |||
(3) Capability of floor structure, on all levels, is limited on west side of building. |
Floor Structure: Slab |
Items
|
3.0.B | Walls (Structural) Comments: Inspected | ||
|
3.1.B | Floors (Structural) Comments: Inspected |
Shrinkage cracks found on concrete floor are not structural. |
Water Source: Public |
Items
|
4.0 | Plumbing Drain, Waste and Vent Systems Comments: Inspected | |
|
4.1 | Plumbing Water Supply and Distribution Systems and Fixtures Comments: Inspected |
Plumbing system has been winterized. |
4.2 | Main Water Shut-Off Device (Describe location) Comments: Inspected | |
|
4.3 | Main Fuel Shut Off (Describe Location) Comments: Inspected | |
|
Electrical Service Conductors: Below ground | Panel Type: Circuit breakers |
Items
|
5.0.A | Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels Comments: Inspected |
5.1.A | Brand Circuit Conductors, Overcurrent Devices and Compatibility of Their Amperage and Voltage Comments: Inspected |
5.2.A | Connected Devices and Fixtures (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) Comments: Inspected |
Electrical Service Conductors: Below ground 480 Volts | Panel capacity: 600 AMP | Panel Type: Circuit breakers |
Electric Panel Manufacturer: Square D | Wiring Methods: Romex Conduit |
Items
|
5.0.B | Service Entrance Conductors Comments: Inspected |
5.1.B | Service and Grounding Equipment, Main Overcurrent Device, Main and Distribution Panels Comments: Inspected |
5.2.B | Brand Circuit Conductors, Overcurrent Devices and Compatibility of Their Amperage and Voltage Comments: Inspected |
5.3.B | Location of Main and Distribution Panels Comments: Inspected, Repair or Replace | ||
|
Heat Type: Forced Air Space heater | Energy Source: Gas |
Items
|
6.0 | Heating Equipment Comments: Inspected |
Gas is not on at time of inspection, unable to inspect beyond a visual inspection. All heaters appear to be in good working condition. |
Type of System: Dry-Valve |
Items
|
7.0.A | Sprinkler Riser Comments: Inspected | |
System is under pressure and main is on at this time. |
7.1.A | Sprinkler Heads Comments: Inspected |
7.2.A | Main Shut Off Location Comments: Inspected | |
|
7.3.A | Fire Doors Comments: Inspected |
Fire doors have been certified last October 2009. |
Type of System: Wet-Valve |
Items
|
7.0.B | Sprinkler Riser Comments: Inspected | ||
Sprinkler riser room located in north east corner of shipping bay is insulated and has a small electric heater. |
7.1.B | Sprinkler Heads Comments: Inspected |
7.2.B | Main Shut Off Location Comments: Inspected |
Sprinkler Shut-off is located outside on north side of the building near west end. |
7.3.B | Fire Doors Comments: Inspected, Repair or Replace | |
|
Items
|
8.0 | Doors Comments: Inspected |
8.1 | Siding Comments: Inspected, Repair or Replace | |
|
8.2 | Walls Comments: Inspected |
8.3 | Floors Comments: Inspected, Repair or Replace |
Some floor tile are loose. |
8.4 | Windows Comments: Inspected |
(PLEASE READ CAREFULLY)
Van Wert Inspections agrees to conduct an inspection for the purpose of informing the CLIENT of major deficiencies in the condition of the property, subject to the UNCONDITIONAL RELEASE AND LIMITATION OF LIABILITY below. The inspection and report are performed and prepared for the sole, confidential and exclusive use and possession of the CLIENT. The report will only include the following:
It is understood and agreed that this inspection will be of readily accessible areas of the building and is limited to visual observations of apparent conditions existing only at the time of the inspection. Latent and concealed defects and deficiencies are excluded from the inspection; equipment, items, and systems will not be dismantled.
Maintenance and other items may be discussed, but they are not a part of our inspection. The report is not a compliance inspection or certification for past or present governmental codes or regulations of any kind.
The inspection and report do not address and are not intended to address the possible presence of or danger from any potentially harmful substances and environmental hazards, including but not limited to radon gas, lead paint, asbestos, mold, mildew, urea formaldehyde, toxic or flammable chemicals, and water and airborne hazards. Also excluded are inspections of and reports on swimming pools, wells, septic systems, security systems, central vacuum systems, water softeners, sprinkler systems, fire and safety equipment, and the presence or absence of rodents, termites and other insects.
UNCONDITIONAL RELEASE AND LIMITATION OF LIABILITY
It is understood and agreed that Van Wert Inspections is not an insurer and that the inspection and reports are not to be intended or construed as a guarantee or warranty of the adequacy, performance, or condition of any structure, item, or system at the property address. The CLIENT hereby releases and exempts Van Wert Inspections and its employees of and from all liability and responsibility for the cost of repairing or replacing any unreported defect or deficiency and for any consequential damage, property damage, or personal injury of any nature.
In the event that Van Wert Inspections and/or its employees are found liable due to breach of contract, negligence, negligent misrepresentation, negligent hiring or any other theory of liability, then the liability of Van Wert Inspections and employees shall be limited to a sum equal to the amount of the fee paid by the CLIENT to Van Wert Inspections for the inspection and report.
CLIENT and Van Wert Inspections agree that should a court of competent jurisdiction determine and declare that any portion of this Agreements is void, voidable or unenforceable, the remaining provision and portion shall remain in full force and effect.
Acceptance and understanding of this agreement are hereby acknowledged:
________________________________ _________________________________
Company Representative Date Client Date